Band-pass Filter Glass
Author:JINGSHENG OPTICAL Date:2016-03-19-

 

This kind of glass only transmits the light within a narrow wavelength range as shown in figure. Its spectral characteristic is composed of maximum transmissivity (TM) wavelength of the peak (lM), front-cut-off wavelength, behind-cut-off wavelength, and half-peak width.    

The wavelength corresponding to the half of the maximum transmissivity are l2 and l1. And the half-peak width is determined by l2 - l1. Front (behind)-cut-off wavelength is corresponding to the wavelength of "zero" transmissivity. But there are a few types which transmissivities of the behind-cut-off wavelengthes can't approach to zero, then they are determined by the transmissivity of the certain wavelength.
Band-pass filter glass is named DTB, and wavelength of the peak is used as its serial number.

Technical Indexes
No.
Type 
Maximum Transmissivity
(TM/λMnm)
Front Cut-off
(T/λnm)
Behind Cut-off
(T/λnm)
Half-peak Width
(λ2-λ1)(nm) 
Thickness (nm)
 
1
DBT400
≥45/400±2
0/320±5
0/525±5
≤90
2
2
DBT435
≥48/435±2
0/340±5
≤2.0/540±5
≤100
4
3
DBT470
≥40/470±2
 
0/340±5
0/600±5
≤115
4
4
DBT500
≥48/500±2
0/380±5
0/630±5
≤100
4
5
DBT530
≥48/530±2
0/420±5
0/670±5
≤95
2
6
DBT545
≥48/545±2
0/400±5
0/720±5
≤100
4
7
DBT560
≥40/560±2
0/435±5
0/725±5
≤104
4
8
DBT600
≥36/600±2
0/470±5
≤1.0/800±5
≤95
4
9
DBT660
≥44/660±2
 
0/500±5
≤0/800±5
≤115
4
10
DBT700
≥28/700±2
≤0.5/570±5
≤0/820±5
≤95
4
11
DBT720
≥50/720±2
0/500±5
≤0/900±5
≤140
4
12
DBT740
≥25/740±2
0/650±5
≤0/900±5
≤85
4


Copyright @ 2010-2011 Nantong JingSheng Optical Instrument Co., Ltd.